Chlorine & Ammonia Gas Masks: Build Your Israeli CBRN Kit
Build your chemical emergency kit around the Israeli 4A1 Black Diamond: a full-face CBRN mask with a secure harness, drinking system, voice emitter and standard 40mm filter connection. Add a sealed Shalon M80 filter for broad NBC preparedness, and select chlorine-rated Type B or ammonia-rated Type K filtration for identified industrial gases. Equip children with Israeli masks or powered hoods. Choose complete kits, practice fitting them at home and keep your family prepared for emergencies.
Shop the Complete Israeli 4A1 + M80 Kit · Choose a Family CBRN Kit
Start With the Israeli 4A1: Full-Face Protection Built for Civil Defense
The Israeli 4A1 Black Diamond is the foundation of a serious household CBRN kit. It covers the eyes, nose and mouth with one full-face assembly. The five-strap harness supports a secure fit; the voice emitter makes communication easier; and the integrated drinking system adds practical hydration during prolonged wear.
The standard EN 148-1 / Rd40 40mm connection gives you a straightforward way to select compatible canisters for different hazards. The 4A1 carries NSN 4240-31-018-6851 and follows SI 4013 Part 5 / EN 136 (identical adoption).
The complete 4A1 Black Diamond CBRN kit includes an unused Israeli civilian-defense mask, a factory-sealed Shalon M80 NBC filter and drinking-tube accessory. One purchase delivers the core equipment for an adult's civil-defense kit.
Chlorine and Ammonia: Choose the Right Filter Chemistry
Start with the full-face 4A1, then choose the filter that matches the chemical. Under EN 14387, Type B is the relevant category for inorganic gases such as chlorine; Type K covers ammonia and certain ammonia derivatives. Choose a canister with a manufacturer-documented rating and capacity for the identified gas.
| Industrial threat | Filter specification to seek | Your CBRN kit |
|---|---|---|
|
Chlorine (Cl₂) Water-treatment systems, industrial transport, chemical facilities |
Chlorine-rated / EN 14387 Type B with documented use limits | Israeli 4A1 full-face mask + compatible chlorine-rated canister |
|
Ammonia (NH₃) Industrial refrigeration, agriculture, manufacturing |
Ammonia-rated / EN 14387 Type K with documented use limits | Israeli 4A1 full-face mask + compatible ammonia-rated canister |
|
General NBC / CBRN readiness Military-agent and airborne particulate preparedness |
Shalon M80 / Type 80 NBC carbon and particulate filter | Complete 4A1 + M80 kit, ready to store alongside specialty filters |
Why the Shalon M80 Has a Strong Scientific Basis for Chlorine Capture
Military-grade impregnated activated carbon is the M80's strength. Shalon specifies ASC 12×30 carbon complying with MIL-C-13724D, combined with high-efficiency glass-fiber particulate media. Its published quality-control program includes challenge testing using cyanogen chloride (CK), phosgene, hydrogen cyanide, chloropicrin and DMMP. Shalon also lists representative performance figures of 100 minutes against CK at 2.4 mg/L and 30 L/min and 250 minutes against DMMP at 3.0 mg/L and 30 L/min.
Independent experimental research has demonstrated chlorine capture by military ASC-family carbon. This provides positive technical evidence for chlorine uptake by the carbon technology used in the M80. The product's confirmed agent testing and high-efficiency particle filter reinforce its value as an NBC preparedness canister.
For an identified chlorine release, use a canister with a documented chlorine capacity for the exposure. A specific service time for chlorine requires breakthrough data for the complete canister under the relevant conditions. For ammonia preparedness, add an ammonia-rated Type K canister to the 4A1 platform.
Buy the 4A1 + M80 Complete Kit · Explore 40mm CBRN Filters
Six Reasons to Choose the Israeli 4A1 CBRN System
| Feature | What you get |
|---|---|
| Full-face coverage | Eyes, nose and mouth covered by a single protective facepiece. |
| Military-standard filter connection | EN 148-1 / Rd40 threaded interface for suitable 40mm canisters. |
| Military NBC filtration | Factory-sealed Shalon M80 with ASC impregnated carbon and particulate filtration included in the complete kit. |
| Hydration | Integrated drinking interface and drinking tube included with the kit. |
| Communication | Built-in voice emitter for clearer communication during mask wear. |
| Powered-air upgrade | Choose ONYX 45 for motor-assisted filtered airflow through a compatible hose and filter. |
ONYX 45: Add Powered Airflow to Your Gas Mask Kit
Make breathing comfort part of the purchase. The Israeli ONYX 45 blower moves filtered ambient air toward the mask at a stated flow of 45 L/min. Its NSN is 4240-31-008-8969. This powered system helps reduce the effort associated with drawing air through a passive filter.
The complete Israeli 4A1 + ONYX 45 kit includes the adult mask, blower, hose and M80 NBC filter. The blower uses four CR123A lithium batteries, purchased separately. Keep batteries alongside the kit and rehearse operation at home.
Shop the Israeli 4A1 + ONYX 45 Powered-Air Kit
Choose CBRN Protection for Every Family Member
Buy the right fit for each person. CBRNMASKS.COM offers a complete Israeli range spanning adults, teenagers, children and infants.
| Who needs protection? | Recommended Israeli kit | Purchase advantage |
|---|---|---|
| Adults and older teens, 15+ | 4A1 Black Diamond + M80 | Full-face mask, voice emitter, drinking tube and factory-sealed NBC filter |
| Adults seeking powered airflow | 4A1 + ONYX 45 | Complete powered-air setup with mask, blower, hose and filter |
| Children, 8–14 | 10A1 Youth CBRN Mask | Youth-sized facepiece, M80 filter and drinking tube |
| Children, 2–8 | Quartz / MAMTAK CBRN Hood | Powered hood, ONYX 45, filter and hydration access |
| Infants, 0–2 | Multipro Infant Powered Hood | Infant-sized system with blower, filter and feeding interface |
| Teens and adults, 13+, with glasses or facial hair | Sapphire + ONYX 45 Hood | Full-head powered hood with filter, blower, hose and drinking system |
Shop Israeli Family CBRN Protection Bundles
CBRN Preparedness: One Family Plan, Four Threat Categories
| CBRN threat | Preparedness priority |
|---|---|
| C — Chemical | Full-face equipment and filtration specifically suited to the identified chemical gas or vapor. |
| B — Biological | High-efficiency particulate filtration and a correctly fitted respiratory system. |
| R — Radiological | Airborne radioactive-particle filtration, shelter and contamination control. |
| N — Nuclear | Airborne fallout-particle filtration, with substantial physical shelter against external radiation. |
Prepare for a Chemical Release Before It Happens
- Equip your household: 4A1 for adults, 10A1 for school-age children, and suitable powered hoods for younger wearers.
- Choose filters by hazard: Store the sealed M80 for NBC readiness; add a documented chlorine-rated Type B or ammonia-rated Type K canister for a known local industrial threat.
- Prepare the complete kit: Keep masks, spare filters, drinking accessories, ONYX 45 units and fresh batteries together.
- Practice in clean air: Learn fitting, seal checks, communications and the drinking connection before an emergency.
- Follow emergency instructions: Move away from the release and follow the authorities' shelter or evacuation directions.
Operational rule: Air-purifying equipment requires adequate ambient oxygen and a known, suitable filtration application. Unknown or immediately dangerous chemical atmospheres require professional responders using appropriate supplied-air equipment. Build your civilian kit for preparedness and safe response — never to enter a release zone.
Frequently Asked Questions
What gas mask should I buy for a chlorine leak?
Start with the Israeli 4A1 full-face mask. Add a compatible canister with documented chlorine capacity, such as a suitably rated Type B filter, and prepare the mask and filter in advance.
Does the Shalon M80 have a scientific basis for chlorine capture?
Yes. The M80 uses military ASC 12×30 impregnated carbon. ASC-family military carbon has demonstrated chlorine uptake in experimental research, while Shalon publishes additional chemical-agent challenge tests for its Type 80 canister. Select a chlorine-rated canister when specific exposure capacity is required.
Which filter type covers ammonia?
Type K. Choose a canister with documented ammonia capacity and a compatible EN 148-1 / Rd40 connection for the 4A1.
What is included in the Israeli 4A1 kit?
The Israeli 4A1 Black Diamond full-face mask, sealed Shalon M80 NBC filter and drinking accessory, with the built-in voice emitter and five-strap harness.
What are the advantages of the ONYX 45 blower?
It supplies 45 L/min of motor-assisted filtered airflow through a compatible system. The complete 4A1 + ONYX 45 kit includes the mask, blower, hose and M80 filter.
Which CBRN gas mask should I buy for a child?
Choose 10A1 for ages 8–14, Quartz/MAMTAK for ages 2–8, and the Multipro infant system for ages 0–2. Select by fit and the correct product configuration.
What is the best CBRN option for glasses or a beard?
The Sapphire + ONYX 45 powered full-head hood offers a practical alternative where a tight facial seal is difficult.
Can the 4A1 help protect the eyes?
Yes. Its full-face design encloses the eyes together with the nose and mouth. Use the correct filter and achieve a reliable face seal.
How should a family respond to a chemical release?
Follow official shelter or evacuation instructions, move away from the exposure source and use the prepared equipment according to its instructions.
What should I order first?
Begin with the complete Israeli 4A1 + M80 kit. Add a matching kit for each family member, the ONYX 45 upgrade where desired and gas-specific filters for known local industrial hazards.
Build Your Israeli CBRN Kit Today
Start with authentic Israeli civil-defense equipment. The 4A1 Black Diamond delivers full-face coverage, hydration, a voice emitter and a standard 40mm filter interface. The sealed Shalon M80 brings military ASC-carbon and high-efficiency particle filtration into the same kit. Complete your household with 10A1 youth masks, purpose-built child hoods and ONYX 45 powered-air options. Choose the right gas-rated specialty canister for a known chlorine or ammonia threat, then keep every system prepared and accessible.
Shop 4A1 + M80 · Upgrade to 4A1 + ONYX 45 · Buy Family CBRN Kits
Technical References
- Shalon — NBC Filter Canister Type 80 Technical Specification
- NIOSH — Chlorine Emergency Response Safety Card
- NIOSH — Ammonia Emergency Response Safety Card
- Dräger — Gas Filter Classification Guide
- Lodewyckx & Verhoeven (2003) — Experimental chlorine adsorption on impregnated and non-impregnated activated carbon, Carbon 41(6)